Loading...
PRODUCT  >>  ON - Line  >> Vanguard Rack II    

   VRTL - Vanguard Rack II

  • On-Line UPS with Rack-Tower Type Design

  • Pure Sinewave with Double Conversion

  • Hot Swappable Battery Replacement

  • Extendable Battery Pack Support

  • Extendable long backup time for devices

  • Overload, Surge, Short Circuit Protection

  • VRTL-1000 / 1500 / 2000 / 3000 / 6000 / 10KVA

  •  UPS
    Model
    VRT-1000-L
    VRT-1500-L
    VRT-2000-L
    VRT-3000-L
    VRT-6000-L
    VRT-10000-L
    Capacity (VA)
    1000
    1500
    2000
    3000
    6000
    10K
    Capacity (Watts)
    900
    1350
    1800
    2700
    5400
    9K
    Form
    Rackmount
    Phase
    Single Phase
    Energy Saving
    Yes - ECO mode Efficiency > 94%

     INPUT
    Voltage
    220 / 230 / 240 Vac
    Voltage Range
    120 ~ 276 Vac < 25% Load
    140 ~ 276 Vac < 50% Load
    160 ~ 276 Vac < 75% Load
    180 ~ 276 Vac < 100% Load
    Frequency Range
    50 / 60 Hz ± 2.5 auto sensing (45Hz to 65Hz user selectable)
    Power Factor
    > 0.97
    Cold Start
    Yes

     OUTPUT
    Rated Power Factor
    0.9
    Waveform
    Pure Sine Wave
    Voltage
    220 / 230 / 240 Vac ± 2% (selectable output voltage)
    Frequency
    50 / 60 Hz ± 0.25 Hz
    Transfer Time
    0 ms
    Harmonic Distortion
    < 5% of THD at non-linear load
    < 2.5% of THD at linear load
    < 5% of THD at non-linear load
    < 3% of THD at linear
    Crest Factor
    3 : 1
    EPO Function
    Yes

     PROTECTION
    Overload Line Mode
    106% - 120% for 30 seconds
    121% - 150% for 10 seconds
    Battery Mode
    101% - 109% for 10 seconds
    110% - 120% for 3 seconds
    Surge Protection
    IEC 61000-4-5 Level 3
    Bypass
    Internal Bypass(Automatic and Manual)
    Short Circuit Protection
    UPS output cut off immediately or protected by input fuse or circuit breaker
    Overload Protection
    UPS automatic power off if overload exceeds 106 ~ 120% of nominal at 30 seconds;
    121 ~ 150% for 10 seconds
    Tele-Communication
    RJ45 x 2
    Alarm
    Buzzer beeps under backup mode, battery low, battery charging fault, and overload

     CHARGER
    UPS
    1A
    UPS Build In
    5A
    --
    Charger Box In
    --
    8A
    Total
    6A
    9A

     BATTERY
    Model
    VRT-1000-L
    VRT-1500-L
    VRT-2000-L
    VRT-3000-L
    VRT-6000-L
    VRT-10000-L
    Voltage (Recommended)
    36V
    48V
    72V
    240V

     MANAGEMENT
    Indicator
    LED & LCD Control Panel
    Communication Port
    RS232, USB(B-type)
    SNMP Slot
    Option
    Audible Alarms
    YES

     PHYSICAL - UPS
    Dimensions (WxDxH)(mm)
    428 x 425 x 84
    428 x 500 x 84
    428 x 635 x 84
    428 x 597 x 130
    428 x 635 x 130
    Weights (Kgs)
    8.2
    11
    14.4
    14.6
    20
    25
    Shipping Dimensions (WxDxH)
    546 x 552 x 206
    550 x 620 x 220
    550 x 750 x 220
    560 x 740 x 273
    565 x 805 x 208
    Shipping Weights (Kgs)
    11.5
    14.6
    18.5
    18.7
    24
    29

     PHYSICAL - Charger Box
    Dimensions
    --
    428 x 597 x 130
    Weights
    --
    9
    Shipping Dimensions
    --
    560 x 740 x 273
    Shipping Weights
    --
    13
    * While 208V output, capacity will derated to 90%

    * Specifications are subject to change without further notice

    * Specifications are for reference, actual information should be based on real product

     Document
     Catalog    
     Monitoring
     UPSMON-Pro Windows    
     UPSMON-Pro Linux    
     SNMPCard - CY504    
     Modbus - NET485    
     DryContact - AS400    
     Tool - UPS FW Upgrade V2.0    



    POWERCOM VRT-L online series with high quality power output and curve shape outfit is the best choice for rack mounting business, IT and Telecom system. High performance VRT-L series with power factor 0.9 and attached with PFC (Power Factor Correction) stabilize fluctuate voltage, including over voltage, lower voltage and provide clean and stable voltage for critical device. POWERCOM VRT-L series applied long-backup operating design, supports extra-long backup time for your critical device. POWERCOM VRT-L online series with easy-reading LCD indicator, clearly shows up UPS status and easy to operate. VRT series attach with selectable mode offers different application for user, such as high efficiency mode, free run mode. POWERCOM VRT-L online series with high performance power factor 0.9 and multi-function design are the best choice for business, IT and telecom system.
     Feedback
     Message Link   
     EMail Link   
     Phone Tel : 886-2-2225-8552