PRODUCT  >>  3 Phase UPS  >> INF - Infinity    

   ONL-II Three Phase

  • Three phase UPS with industrial grade design

  • IGBT modular design and dry contact function

  • Digital signal processor control (DSP)

  • Intellectual heat-radiating mode

  • Isolate transformer equip

  • Human-Voice alarm reminding

  • ONLII33 - 10K ~ 250K

  •  UPS
    Model
    ONLII-10K33
    ONLII-15K33
    ONLII-20K33
    ONLII-30K33
    ONLII-45K33
    ONLII-60K33
    Capacity(VA)
    10K VA
    15K VA
    20K VA
    30K VA
    45K VA
    60K VA
    Capacity(Watts)
    8K KW
    12K KW
    16K KW
    24K KW
    36K KW
    48K KW

     INPUT
    Grid System
    3 Phase + Neutral + Ground
    Voltage
    190 / 200 / 208 / 220 / 380 / 400 / 415 / 440 Vac (Line-Line)
    Voltage Range
    152 - 528 Vac (Line-Line)
    Frequency
    50 / 60 Hz (Auto Sensing)
    Frequency Range
    45 - 65 Hz

     OUTPUT
    Inverter Voltage
    190 / 200 / 208 / 220 / 380 / 400 / 415 / 440 Vac (Line-Line)
    Inverter Frequency
    50 / 60 Hz
    Output Power Factor
    0.8 - 1.0 Lagging
    Voltage Precision
    ± 1% (100% Linear Load)
    Transient Response
    Linear Load 0 - 100% < 5%
    Transient Rescovery
    ±2% < 50ms
    Output THDv
    < 3% (Linear Load)

    Inverter Overload
    > 100%, 30 min
    > 125%, 10 min
    > 150%, 1 min
    Frequency Regulation
    50/60 Hz ± 0.1%
    Synchronized Range
    Default Range : ±5Hz
    Synchronized Slew Rate
    Default Range : 1Hz/s

     Battery and Charger
    Battery Voltage
    10-80K(120/208VAC) : 192VDC, 12V-16 pcs as one set
    10-120K(220/380VAC) : 360VDC, 12V-30 pcs as one set
    Charger Voltage Precision
    1%
    Charger Power
    Battery 16 pcs-220VDC, Battery 30 pcs-410VDC, Battery 32 pcs-435 VDC
    Current : Depending on the model used 1.5, 2.5, 3, 5, 10, 15, 20, 30, 40, 50A
    Options and Automatic Current Limiting Function can be set

     Bypass Input
    Voltage
    190 / 200 / 208 / 220 / 380 / 400 / 415 / 440 VAC (Line-Line)
    Voltage Range
    152 - 528 VAC(Line-Line)
    Frequency
    50 / 60 Hz
    Frequency Range
    45 - 65 Hz
    Bypass Overload
    > 100%, 30 min
    > 125%, 10 min
    > 150%, 1 min

     Efficiency
    Normal Operation
    > 85%
    > 86%
    > 88%
    Battery Operation
    > 87%
    > 88%
    > 90%

     Static Transfer Switch
    Inverter to Bypass
    0 ms
    Bypass to Inverter
    0 ms
    Transfer Efficiency
    > 99%

     Environment
    Operation Temperature
    0 - 40°C
    Storage Temperature
    -15°C ~ 60°C
    Relative Humidity
    0 - 95% non-condensing
    Noise
    Less than 60dBA
    Altitude
    Normal Load : < 1000m
    Load derated 1% per 100m from 1000 to 2000m

     Physical Data
    Dimension
    (WxDxH)(mm)
    530 x 859 x 1010
    810 x 810 x 1900
    Weight (kg)
    310
    340
    368
    398
    515
    567

     Alarm
    Event Log
    Detail ups status description not use error code, record item number of event max 2400
    Network
    Network connection port (10/100 Base. T) and remote monitor control, not use SNMP card
    Dry Contact
    Max item : 20 status, programmable select : 4 item

     System
    Display
    7" TFT LCD touch screen indicator
    Interface
    Standard : RS232 / RS485 / Dry Contact
    Optional : SNMP
    Other Function
    Standard : Battery Cold Start
    Optional : Parallel Kit
    * While 208V output, capacity will derated to 90%

    * Specifications are subject to change without further notice

    * Specifications are for reference, actual information should be based on real product

     UPS
    Model
    ONLII-80K33
    ONLII-100K33
    ONLII-120K33
    ONLII-160K33
    ONLII-200K33
    ONLII-250K33
    Capacity(VA)
    80K VA
    100K VA
    120K VA
    160K VA
    200K VA
    250K VA
    Capacity(Watts)
    64K KW
    80K KW
    96K KW
    128K KW
    160K KW
    200K KW

     INPUT
    Grid System
    3 Phase + Neutral + Ground
    Voltage
    190 / 200 / 208 / 220 / 380 / 400 / 415 / 440 VAC (Line-Line)
    Voltage Range
    152 - 528 VAC Line-Line)
    Frequency
    50 / 60Hz (Auto Sensing)
    Frequency Range
    40 - 65 Hz

     OUTPUT
    Inverter Voltage
    190 / 200 / 208 / 220 / 380 / 400 / 415 / 440 Vac (Line-Line)
    Inverter Frequency
    50 / 60 Hz
    Output Power Factor
    0.8 - 1.0 Lagging
    Voltage Precision
    ± 1% (100% Linear Load)
    Transient Response
    Linear Load 0 - 100% < 5%
    Transient Rescovery
    ±2% < 50ms
    Output THDv
    < 3% (Linear Load)

    Inverter Overload
    > 100%, 30 min
    > 125%, 10 min
    > 150%, 1 min
    Frequency Regulation
    50/60 Hz ± 0.1%
    Synchronized Range
    Default Range : ±5Hz
    Synchronized Slew Rate
    Default Range : 1Hz/s

     Battery and Charger
    Battery Voltage
    80K(120/208Vac) : 192VDC, 12V-16 pcs as one set
    80-120K(220/380Vac) : 360VDC, 12V-30 pcs as one set
    160-250K(220/380Vac) : 384VDC, 12V-32 pcs as one set
    Charger Voltage Precision
    1%
    Charger Power
    Battery 16 pcs-220VDC, Battery 30 pcs-410VDC, Battery 32 pcs-435 VDC
    Current: Depending on the model used 1.5, 2.5, 3, 5, 10, 15, 20, 30, 40, 50A
    Options and Automatic Current Limiting Function can be set

     Bypass Input
    Voltage
    190 / 200 / 208 / 220 / 380 / 400 / 415 / 440 Vac (Line-Line)
    Voltage Range
    152 - 528 VAC(Line-Line)
    Frequency
    50 / 60 Hz
    Frequency Range
    45 - 65 Hz
    Bypass Overload
    > 100%, 30 min
    > 125%, 10 min
    > 150%, 1 min

     Efficiency
    Normal Operation
    > 89%
    > 90%
    Battery Operation
    > 91%
    > 92%

     Static Transfer Switch
    Inverter to Bypass
    0 ms
    Bypass to Inverter
    0 ms
    Transfer Efficiency
    > 99%

     Environment
    Operation Temperature
    0 - 40°C
    Storage Temperature
    -15°C ~ 60°C
    Relative Humidity
    0 - 95% non-condensing
    Noise
    Less than 60dBA
    Altitude
    Normal Load : < 1000m
    Load derated 1% per 100m from 1000 to 2000m

     Physical Data
    6-Dimension
    (WxDxH)(mm)
    810 x 810 x 1900 (220 / 380VAC)
    1400 x 1000 x 1800 (220 / 380VAC)
    Weight (kg)
    677
    680
    730
    1035
    1055
    1075
    12P-Dimension
    (WxDxH)(mm)
    1300 x 810 x 1900 (220 / 380VAC)
    1400 x 1000 x 1800 (220 / 380VAC)
    Weight (kg)
    810
    860
    910
    1035
    1055
    1075

     Alarm
    Event Log
    Detail ups status description not use error code, record item number of event max 2400
    Network
    Network connection port (10/100 Base. T) and remote monitor control, not use SNMP card
    Dry Contact
    Max item : 20 status, programmable select : 4 item

     System
    Display
    7" TFT LCD touch screen indicator
    Interface
    Standard : RS232 / RS485 / Dry Contact
    Optional : SNMP
    Other Function
    Standard : Battery Cold Start
    Optional : Parallel Kit
    * While 208V output, capacity will derated to 90%

    * Specifications are subject to change without further notice

    * Specifications are for reference, actual information should be based on real product

     Document
     Catalog    
     Monitoring
     SNMPCard - CY504    
     SNMPCard - BY506    



    POWERCOM ONLII-33 three phase UPS with high performance UPS are the best choice for data center, telecom system and industrial application. POWERCOM ONLII-33 three phase UPS with colorful touch screen are available to clearly shows up UPS status. ONLII-33 three phase UPS with dry contact function for signal control. ECO energy – power saving ONLII-33 are intellectual heat radiation control, it reduce noise and extending service life. ONLII-33 with upgraded VIS system and built-in maintains administrator is easier for management and maintenance. High performance POWERCOM three phase ONLII-33 UPS with dry contact function, eco energy saving design, audible alarm system are suitable for telecom, datacenter and industrial usage.